F. Manual Ignition
Lightingtheremanuallywillnotbenecessaryunlessthe
ignitersystemfails.
1. Flip the Igniter Switch Down intothe“MANUAL-LIGHT”
position.SeeFigure4.8.
2. Open inner and outer ash doors as shown in Figures
5.1 thru 5.3. Located in the maintenance and service
sections of this manual.
3. Fill burnpot with pellets as shown in Figure 4.9. Only
ll level with the front edge. ( DO NOT OVERFILL )
4. Have matches or other ignition source ready.
5. Turn Mode Selectorto“SERVICE”Figure4.10.
Figure 4.8
Figure 4.9
Figure 4.10
ThiswillstartthecombustionblowerandallowtheESPto
controlthereinrelationtotheTempDialsetting1through7.
OncethereiswellestablishedtheTempDialcanremainon
anynumbersettingdesired,orchangedtothe“AUTOMATIC”
setting.Ifyouchangeto“AUTOMATIC”remembertosetthe
TempDialtodesiredtemperature.
NOTE: When the Switchis set to Manual-Light in the
“AUTOMATIC” mode, the wall control will function asin
Auto-Lightexcepttherewillnotbeallowedtogoout.Itwill
onlybeallowedtogotoaminimumburnratebetweenthe
timesthewallcontroliscallingforheat.Thisrateisabout1
poundoffuelperhour.
7. Light the starting gel with a match.
8. Close the doors
Therewilllightandthecontrolwill adjust the re to the
proper levelaccording to the temperature readingat the
wallcontrol.
CAUTION
!
• Avaporashcouldoccuriftoomuchtimeisallowed
topassbeforelightingthestartinggel.
• Care mustbe taken not to get starting gel on your
handsor clothing.Seriousburns couldoccurduring
thelightingprocess.
• Never try to apply more starting gel to an already
burningre,orarewithsmolderingpellets.
6. Apply starting gel as shown in Figure 4.11.
NOTE: Stirring the starting gel into the pellets usually
allows the re to become established quicker.
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN
FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR
SIMILAR LIQUIDS TO START OR “FRESHEN UP” A
FIRE IN THIS FURNACE. KEEP ALL SUCH LIQUIDS
WELL AWAY FROM THE FURNACE WHILE IN USE
WARNING
!
STARTER
GEL
Figure 4.11