Harman® • PF-120 Owner’s Manual_R3 • 2014 -___ • 10/147
3-90-08120c
C. Control Explanation
Status Light
Will be lit in either automatic
or service mode when
pointer is not within off
position band except after
normal shut down.
Combustion Blower Light
Indicates Power to
combustion blower
Feed Motor Light Indicates
Powertothefeedmotor.
Temp dial
The“TempDial”shouldbeinthe“NormalSetting”positionexceptwhenservice
workisbeingdone.Italsoallowsyoutoadjusttheretemperaturewhenthe
“ModeSelector”isin“ServiceMode”usingthescalemarkedfrom1to7.
Note:Duetovariationsintheelectronicsofthecontrolboardandwallcontrol
this is an approximate temperature and may vary +/- 2°
Feed adjuster
Setsthemaximumfeedrate
Test
Runs all motors at full speed
for one minute to check
operation. After one minute
the combustion blower will
go to it’s minimum speed
and remain there. This is to
allow for low draft voltage
adjustment.
Low Fuel Light
Indicates that fuel in the
hopper is low and needs to
be relled. Low FuelLED
stays on for 15seconds
after new fuel covers
sensor.
Igniter Light
Indicates power to the
igniter
Lighting Mode Selector
Switched between Auto and
Manuallighting
Mode Selector
Seeexplanationbelow.
Diagnostic Display Port
RequiresspecialDDMmonitor
supplied exclusively to service
technicians.
Power Light
Indicates power to the
control, and is also used
during “Test” to check the
LowFuelSensoroperation.
LED will blink toindicate
battery back-up shutdown
if applicable.