ORP Setting If ORP controls chlorination (page 10), adjust setpoint from 400mV to 900mV. If
ORP does not control chlorination, adjust from 0% to 100%.
On/Off Enable and disable ORP sensing and chlorine generation.
Schedule Enable and disable chlorine generation based on time. You can set a unique sched-
ule for the chlorinator that will override filter pump settings. See the OmniLogic
manual for details on how to create schedules.
SC Superchlorinate allows you to select a continuous run time for maximum chlorina-
tion.Selectaruntimebetween0-96hours.TheOmniLogicwilloverridepump
schedules and generate chlorine continuously for this amount of time.
Diag Displays electrical diagnostics for the Turbo Cell.
Controlling ORP with the OmniLogic
Follow these steps to adjust the desired ORP level:
1. IMPORTANT: Balance the pool water to the ideal levels shown in the OmniLogic manuals,
including pH, total alkalinity, cyanuric acid, hardness and salt level.
2. Adjust the chlorine to the ideal level as well; e.g. 1-3 ppm free chlorine. This chlorine level is
what we want to maintain.
3. Afterallowingthesystemtorunfor30-60minutes,observewhattheSenseandDispense
system reports as the pool water ORP level.
4. Set the ORP setpoint setting to this reported ORP level.
5. Monitor the free chlorine and ORP every day for 1 week. If adjustments to the ORP setpoint
areneeded,makeadjustmentsinincrementsof10or20mVunits—LARGEADJUSTMENTS
OF THE ORP SETPOINT SHOULD NOT BE NECESSARY IF YOU STARTED WITH A BALANCED