POOL THAT HAD THE PROPER AMOUNT OF FREE CHLORINE.
6. Ifthesystemisnotstabilizing(ordoesnotseemtobestabilizing)thereare3thingsyoucan
do:
a. Clean the probe
b. Rebalance the pool –including the free chlorine level
c. Check for combined chlorine—if high (>0.5ppm), shock treat with chlorine or non-
chlorine shock
Controlling pH with the OmniLogic
Plaster pools and pools serviced by salt-chlorine generators typically cause a slow pH rise which
must be managed. With the Sense and Dispense technology, CO
2
or acid is dispensed into the
filter system’s return water as needed until the pH probe reports proper pH level.
The Hayward AQL-CHEM2(-240) are CO
2
dispensing systems that eliminate the need to handle
acid and are economical and efficient methods for effective pH control. When the CO
2
gas is
injected into water, it dissolves and becomes carbonic acid, a weak acid that is very effective at
lowering pH but becomes self-limiting if over-fed.
CAUTION: IF YOU CHOOSE AN ACID FEEDER FOR pH CONTROL, additional safety precautions are
requiredtoensurethatanequipmentmalfunctionisdetected.Greatcaremustbetakenwhenin-
stalling, maintaining and operating acid pump feed systems. Acid is dangerous to handle, and will
harm people and equipment if not properly contained, transported, poured, stored, and dispensed.
CAUTION: Equipment failure can potentially cause too much acid to be dispensed into the water,
causing an equipment and health hazard which would not be detectable without the use of inde-
pendent pH measurement.
• Alwaysusea4:1dilutionintheacidfeedsystem.
• CAUTION:Topreventaviolentreaction,ALWAYSADDACIDTOWATER,neveraddwatertoacid
to dilute it. Some use the rhyme “Remember, do as you oughta- add acid to water”
• Strictlyfollowtheacidvendor’ssafetyandhandlingprotocolsincludinghand,bodyandeye
protection when transferring or handling acid.
• Choosea5gallonperdayacidfeedpumptokeepowratelow.
• Limittheavailableacidreservoirto1gallonper15,000gallonsofwater.Thislimitstheavail-
able acid in the event that equipment malfunctions and empties the tank into the pool or spa.
• OnlyaproperlyinstalledandmaintainedsystemwillcontrolthepHandsanitizerlevelsofthe
water.
• WARNING:Ifacidisnotdilutedproperlyorthefeedpumpisoversized,itwillovershootthepH
correction.
• Atleastmonthly,useanindependentpHandchlorinetestkittoverifythatpHandchlorineare
at a safe level. If the probes are broken, depleted, dirty, fouled with oils, lotions, or other con-
taminants, they can report inaccurate result to the system causing incorrect water chemistry,
which at worst, could harm people or equipment.
• ChecktheOmniLogic’sdisplayeachdaybeforeenteringthewater.Ifthereisanalarm,follow
the troubleshooting guide to understand and rectify the condition. If the display is blank, or
reporting a communications error, troubleshoot the equipment and rectify the failure before
entering the water.