Water Detected
0 Times
Drive Overcurrent
0 Times
Drive Over Current Causes
1. Unit caught under a ladder
2. Debris caught in traction drive
belt and or pulleys under side cover.
3. Riding or standing on unit during operation.
4. Defective wheel tube bearings or side cover idler bearings
5. Defective drive motor.
Number of times the water has
contacted the sensor inside the
motor box. Continuous
contact will stop operation of the
unit. Severe water damage will
cause a ‘Communication Failure’
when hooked to the scanner.
Using The Scanner Tool
Page 34
Number of times the drive motor has realized
an over load condition. Unit will stop after 3-5
seconds in this condition.