• DOME SPEED: The manual movement speed of the dome can be set from level 1 to 10.
• SCAN SPEED: The scan speed defines the scan degree per second of pan scan, tilt scan, and panoramic
scan. The scan speed is adjustable from level 1 to level 40 and the higher the level, the faster the scan
speed.
• PRESET SPEED: The speed of calling a preset can be set from level 1 to 8. A higher level corresponds to a
faster speed to call a preset.
Setting Limits
Purpose:
The limits are user-configurable positions that limit the panning and tilting area of the speed dome. There
are left, right, up, and down limits to define an area.
1. Move the cursor to ENABLE LIMIT and click FOCUS+ to set it ON to enable this feature. Click IRIS+ to
confirm the new settings.
2. Move the cursor to SETTING STOPS and click IRIS+. You will see the message
SET LEFT LIMIT
on the
screen.
3. Click the direction buttons in the PTZ panel to configure the left limit. Click IRIS+ to confirm the new
settings.
4. Follow the prompts to configure the right, up, and down limits on the menu.
NOTE: The new limit will overwrite existing ones by default.
5. You can clear the defined limits. Click IRIS+ to enter CLEAR LIMITS and click IRIS+ again to clear the
stops.
Elevation Set
You can set the SET ELEVATION as ON to increase the elevation angle range of the speed dome or set it as
OFF to disable the function.
NOTE: The range of the elevation angle varies by speed dome model.
Configuring Presets
Purpose:
A preset is a user-defined monitoring position/point. Simply call the preset number to change the monitor
scene to the defined position.
1. Move the cursor to enter the preset configuration submenu: MAIN MENU > DOME SETTINGS > PRESETS
2. Choose the preset number:
A. Move the cursor to PRESET NUM.