B. Click the up and down direction buttons to select the alarm number to be configured.
C. Click IRIS+ again to confirm and exit editing mode of this column.
NOTE: You can configure up to two alarm inputs.
3. Move the cursor to ALARM SETTING and click the IRIS+ to enter the setting alarm submenu.
4. Configure the alarm input.
A. Move the cursor to ALARM INPUT and click the IRIS+ to enter the editing mode.
B. Click the up and down direction buttons to set the input status. You can configure it as OPEN
(Normally open), CLOSE (Normally closed) or OFF (disable the alarm input).
C. Click IRIS+ again to confirm.
NOTE: If you set the status as OPEN, alarm will be triggered by high electricity level; if you set the
status as CLOSE, alarm will be triggered by low electricity level; if you set the status as OFF,
it will be triggered when this input channel is shut off.
5. Configure the alarm linkage action to specify the linked action when an alarm occurs.
A. Move the cursor to ALARM AC and click the IRIS+ to enter the editing mode.
B. Click the up and down direction buttons to choose the desired linkage action. You can set the
alarm action as preset from 1 to 8, pattern from 1 to 5, patrol from 1 to 10, panning scan, tilting
scan, panoramic scan, day mode, night mode, or none. You can also set the alarm output for the
alarm. Refer to
Section 3.5.3
Configuring Auxiliary Alarm Output for details.
6. Configure alarm priority. Enter the PRIORITY menu and set the alarm priority as HIGH, MIDUEM or LOW. If
multiple alarms with different priorities are triggered at the same time, the dome responds only to the
alarm with the highest priority. If multiple alarms with the same priority are triggered at the same time,
then the dome will respond to each alarm according to the defined alarm sequence.
Configuring Alarm Parameters
Purpose:
You can set the alarm related parameters, including linkage action interval, alarm duration, and dome
activity resumption by following the instructions below
1. Enter the alarm parameter configuration menu: MAIN MENUS > DOME SETTINGS > ALARMS.
2. Configure the alarm sequence interval.
NOTE: When more than one alarm of the same priority occurs at the same time, the speed dome
will respond to one alarm first and then respond to the next one after the user-defined
interval. You can set this on the SEQUENCE submenu from 1 to 200 seconds.
3. Configure the alarm rest delay. If a linkage action has already been triggered by an alarm input, the