2) Click Detecon Area.
3) Click on the live image to draw the boundaries of the detecon area, and right click to
complete drawing.
7.
Oponal: Set the minimum size and the maximum size for the target to improve detecon
accuracy. Only targets whose size are between the maximum size and the minimum size trigger
the
detecon.
1) Click Max. Size, and drag the mouse on live image. If you want to change the size, click the
buon and draw again.
2) Click Min. Size, and drag the mouse on the live image. If you want to change the size, click the
buon and draw again.
8.
Set
detecon parameters.
Sensivity It stands for the sensivity of detecng an target. The higher the value is,
the more easily the target is detected.
Detecon
Target
You can specify the object type, and the device only detects the selected
type of objects.
Figure 8-7 Draw Area
9.
Click Save.
10.
Repeat above steps to set other regions.
11.
Set arming schedule. See
Set Arming Schedule .
12.
Set linkage method. See
Linkage Method Sengs .