8.3 Detecting Video Loss
Purpose:
Detect video loss of a channel and take alarm response action(s).
Steps:
1. Enter Video Loss interface of Camera Management and select a channel you want to detect.
Menu> Camera> Video Loss
Figure 8. 11 Video Loss Setup Interface
2. Set up handling method of video loss.
Check the checkbox of Enable Video Loss Alarm.
Click button to set up handling method of video loss.
3. Set arming schedule of the channel.
Select Arming Schedule tab to set the channels arming schedule.
Choose one day of a week and up to eight time periods can be set within each day. Or you can click the
Copy button to copy the time period settings to other day(s).
Time periods shall not be repeated or overlapped.
Figure 8. 12 Set Arming Schedule of Video Loss
Repeat the above steps to set arming schedule of other days of a week. You can also use Copy button to
copy an arming schedule to other days.

Table of Contents

Other manuals for HIKVISION DS-7216HGHI-SH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-7216HGHI-SH and is the answer not in the manual?

HIKVISION DS-7216HGHI-SH Specifications

General IconGeneral
Product colorBlack
Channels quantity16 channels
Total storage capacity12000 GB
Video compression formatsH.264
Playback resolutions supported1920 x 1080, 1280 x 1024, 1280 x 720, 1024 x 768
Audio input1
BNC input ports16
USB 2.0 ports quantity2
Ethernet interface typeFast Ethernet, Gigabit Ethernet
Supported network protocolsTCP/IP, PPPoE, DHCP, DNS, DDNS, NTP, SADP, SMTP, SNMP, NFS, iSCSI, UPnP, HTTPS
HDD interfaceSerial ATA
Power requirements12V DC
Power consumption (typical)20 W
Operating temperature (T-T)-10 - 55 °C
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Dimensions (WxDxH)380 x 290 x 48 mm

Related product manuals