Note
If you select Access Controller: If connect the device to a terminal via the RS-485 interface, set
the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address
according to the door No.
4.
Tap the back icon at the upper le corner and you should reboot the device if you change the
parameters.
7.2.4 Set Wiegand Parameters
You can set the Wiegand transmission direcon.
Steps
1.
Tap Comm.
(Communicaon Sengs) on the Home page to enter the Communicaon Sengs
page.
2.
On the Communicaon Sengs page, tap Wiegand to enter the Wiegand tab.
Figure 7-7 Wiegand Sengs
3.
Enable the Wiegand funcon.
4.
Select a transmission direcon.
●
Output: A face recognion terminal can connect an external access controller. And the two
devices will transmit the card No. via Wiegand 26 or Wiegand 34.
●
Input: A face
recognion terminal can connect a Wiegand card reader.
5.
Tap to save the network parameters.
DS-K1T343 Series Face Recognion Terminal User Manual
33