Mounting and Connection Instructions - Door module RS485 19
6.1.8 Reader type and card coding
Input type: CLOCK/DATA or Wiegand-interface
Output type: RS-485
Reader type Remarks
Novar contactless Output RS-485
Settings for card coding in the corresponding Novar access control software.
HID-Wiegand Output RS-485
Settings for card coding in the corresponding Novar access control software:
Wiegand esser var. DIN
(Wiegand 26 Bit card)
System no.: Start: 1, Digits: 4
ID no. Start: 5, Digits: 5
Version no.: Start: 10, Digits: 1
Wiegand esser var. DIN
(Wiegand 34 Bit card)
System no.: Start: 1, Digits: 5
ID no.: Start: 6, Digits: 5
Version no.: Start: 11, Digits: 2
Wiegand var. DIN
System no.: Start: 0, Digits: 0
ID no.: Start: 5, Digits: 16
Version no.: Start: 0, Digits: 0
Wiegand esser
System no.: Start: optional, Digits: optional
ID no.: Start: optional, Digits: optional
Version no.: Start: optional, Digits: optional