Excel 800 Description of Extra Parts
65 EN1B-0375GE51 R0910
XS814 Auxiliary Terminal Package
Features
Type: XS814 Auxiliary Terminal Package
For mounting onto already-installed pluggable I/O
modules in order to equip them with additional terminals.
Each unit consists of two terminal blocks (the "A" block
and the "B" block), each with seven terminals with a
maximum load of 12 A.
Fig. 94 XS814 Auxiliary Terminal Package
Terminal Assignment
1 12 23 34 4
5 5
6 6
A1 B1A2 B2A3 B3A4 B4
A5 B5
A6 B6A7 B7
7 7
Fig. 95 Terminal assignment and internal connections of
XS814 Auxiliary Terminal Package
XS830 Auxiliary Terminal Package
Features
Type: XS830 Auxiliary Terminal Package
For mounting onto the top and/or bottom of already-
installed XF830A mixed I/O modules and the top of
already-installed XFU830A mixed I/O modules in order to
equip them with additional terminals.
Each unit consists of two groups of terminal blocks
(the "A" block and the "B" block), each with nine
internally-connected push-in terminals with a maximum
load of 12 A.
A1 A2 A3 A4 A5 A6 A7 A8 A9 B1 B2 B3 B4 B5 B6 B7 B8 B9
Fig. 96 XS830 Auxiliary Terminal Package
Terminal Assignment
1 12 23 34 4
5 5
6 6
A1 B1A2 B2A3 B3A4 B4
A5 B5
A6 B6A7
A8 A9
B7
B8 B9
7 8 9 7 8 9
Fig. 97 Terminal assignment and internal connections of
XS830 Auxiliary Terminal Package
XS831 Auxiliary Terminal Package
Features
Type: XS831 Auxiliary Terminal Package
For mounting onto the top and/or bottom of already-
installed XF830A mixed I/O modules and the top of
already-installed XFU830A mixed I/O modules in order to
equip them with additional terminals.
Two groups of four pairs of push-in terminals (A1B1,
A2B2, … A8B8, each with a 499 resistor) for converting
0…20 mA signals (maximum load per resistor = 25 mA)
into 0…10 Vdc signals, and one push-in ground terminal
per group. See also Fig. 89 and Fig. 90.
Note
The ground side of each of the eight incoming 0…20 mA
signals (A1B1, A2B2, … A8B8) must be connected to a
ground terminal.
A1 B1 A2 B2
A3 B3
A4 B4 G1 G2
A5 B5 A6 B6
A7 B7
A8 B8
Fig. 98 XS831 Auxiliary Terminal Package
Terminal Assignment
1 12 2
3 3
4 4
5 5
6 6
A1 B1 A2 B2
A3 B3
A4 B4 G1
A5 B5 A6 B6
A7
A8
B7
B8
G2
7 8 9 7 8 9
Fig. 99 Terminal assignment and internal connections of
XS831 Auxiliary Terminal Package

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Excel 800 SYSTEM and is the answer not in the manual?

Honeywell Excel 800 SYSTEM Specifications

General IconGeneral
BrandHoneywell
ModelExcel 800 SYSTEM
CategoryController
LanguageEnglish

Related product manuals