EasyManuals Logo
Home>Honeywell>Security System>LYNX Touch L5200 Series

Honeywell LYNX Touch L5200 Series Programming Guide

Honeywell LYNX Touch L5200 Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
- 23 -
5800 Series Transmitter Loop Numbers
LOOP 1
5806/5806W3/5807
5808/5808LST/5808W3
ENROLL AS
"RF"
LOOP 1
LOOP 1
5809
ENROLL AS
"RF"
581 8 MNL
ENROLL AS
"RF"
LOOP 1
LOOP 1
LOOPS
1 - 3
LOOP 1
LOOP 1
5814
ENROLL AS
"RF"
5800-002-V2
580 4 BD/ 5 8 04B DV
ENROLL AS
"BR"
PROGRAM HOUSE ID
LOOP 4
LOOP
3
LOOP 1
LOOP 2
5804E
ENROLL AS "BR"
582 2 T
ENROLL AS
"RF"
587 7
581 6 MN
ENROLL AS
"RF"
LOOP 1
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP 2
LOOP 2
(REED)
LOOP 3
(TERMINALS)
582 8 /58 2 8 V
PRO GRA M
HOUSE ID
582 1
ENROLL AS
"RF"
582 0 L
ENROLL AS
"RF"
581 9 S (WH S & B R S)
ENROLL AS
"RF"
LOOP 1
(INTERNAL
SHOCK
SENSOR
LOOP 2
(REED)
581 9
ENROLL AS
"RF"
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(TERMINALS)
580 0 WAV E
PRO GRA M
HOU S E ID
580 0 PIR - OD
ENR O LL AS " R F"
580 0 PIR / 580 0 PIR - C OM
ENR O LL AS " R F"
581 1
ENR O LL AS " R F"
580 0 PIR - RES
ENR O LL AS " R F"
580 0 Mic r a
ENR O LL AS " R F"
580 0 CO
ENR O LL AS " R F"
580 0 SS1
ENR OLL A S " RF"
580 0 RL
SET H O USE I D
LOOP 1
LOOP 1
(LOW
SENSITIVITY
LOOP 2
(HIGH
SENSITIVITY)
LOOP 3 (TEMP)
LOOP 4 (TAMPER)
LOOP 1
(HIGH
SECURITY)
LOOP 2
(STANDARD
SECURITY)
LOOP 3 (TILT MODE)
LOOP 4 (TAMPER)
LOOP 1
(LOW
SENSITIVITY
LOOP 2
(HIGH
SENSITIVITY)
LOOP 3 (TEMP)
LOOP 4 (TAMPER)
5834-2
ENROLL AS "BR"
5834-4
ENROLL AS "BR"
LOOP
1
LOOP
1
LOOP
1
LOOP
1
587 8
ENROLL AS
"BR"
5870API
ENROLL AS
"RF"
5869
ENROLL AS
"RF"
585 3
ENROLL AS
"RF"
ARMED
READY
MESSAGE
MIC
LOOP 1
(LOW SENSITIVITY)
LOOP 2
(HIGH SENSITIVITY)
589 8
ENROLL AS
"RF"
LOOP 4
LOOP 1
LOOP 2
LOOP 3
SERIAL #1
LOOP 3
SERIAL #1
LOOP 4
SERIAL #2
LOOP 3
SERIAL #1
LOOP 2
SERIAL #1
LOOP 1
SERIAL #2
LOOP 2
3
AWAY
STAY
1
2
4
OFF
ON
SERIAL #1
LOOP 4
SERIAL #2
LOOP 1
SERIAL #2
LOOP 2
SERIAL #2
LOOP 3
SERIAL #1
LOOP 1
SERIAL #2
LOOP 4
LOOP 3
581 6
ENROLL AS
"RF"
LOOP 1
(TERMINALS)
LOOP 2
(REED)
SERIAL #2
LOOP 1
SERIAL #1
LOOP 3
SERIAL #1
LOOP 2
Notes: (1) The 5806W3 smoke detector must be used in SIA applications.
(2) Button type (BR) devices send only fault and low battery signals; no restore or check-in signals.
Supervised RF (RF) devices send periodic check-in signals, faults, restore and low battery signals.
Unsupervised RF (UR) devices send periodic check-in signals, faults, restore and low battery signals but the control
does not supervise the check-in signals.
(3) If an external sounder is required, the 5800WAVE should be used.
(4) The 5804E and 5834-4 encrypted (High-Security) devices must be activated while the system is in Go/No-Go Test
Mode. Refer to the transmitter’s Installation Instruction for complete details. The system will confirm the enrollment of
the encrypted device by beeping two times
(5) The 5800PIR-OD, 5800RL, 5800SS1, 5804E, 5804BD, 5804BDV, 5814, 5816TEMP, 5821, 5828/5828V, 5877 and
5878 wireless transmitters have not been evaluated by UL/ETL
UL
ULUL
UL
The 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5814, 5816TEMP, 5819, 5819S(WHS & BRS), and
5828/5828V wireless transmitters
have not been evaluated by UL
.

Other manuals for Honeywell LYNX Touch L5200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell LYNX Touch L5200 Series and is the answer not in the manual?

Honeywell LYNX Touch L5200 Series Specifications

General IconGeneral
BrandHoneywell
ModelLYNX Touch L5200 Series
CategorySecurity System
LanguageEnglish

Related product manuals