System 57 Quick Start Guide 05701-M-5026 MAN0839 Issue 1
9.2 Environmental
Operating Temperature: -5
º
C* to +55
º
C (*0° for EXAM approved systems).
Storage Temperature: -25
º
C to +55
º
C.
Humidity: 0 to 90% RH. Non-condensing.
9.3 RFI/EMC Conformity
EMC Directive 89/336/EEC Conforms to: EN 50270:1999
Special conditions: The optional recorder output may be in error by ±5% fsd during some
test conditions of the industrial standard if the connecting cables are not shielded with an
outer screened cable.
Radiated Susceptibility: 10V/m over 50kHz to 1GHz. Note: The Part 2
conformity refers to installations using the System 57
cabinet. For System 57 racks not supplied in cabinets
or supplied in GRP cabinets, the conformity is to Part 1.
LV Directive 73/23/EEC
Constructed in accordance with good engineering practice. Guided by the principles of
EN61010/1 1990/1992.