Security Codes & Authority Levels
(contd)
How to Assign User Codes and Attributes
The following lists the various command strings for adding user codes and attributes.
Refer to the User Setup chart at the back of this manual for factory defaults of
user attributes and to keep a record of user programming.
NOTE:
Partition Master codes (VISTA-20P/PS Series only) apply only to those user
numbers previously assigned (by the system master/installer) to the partition masters
partition.
Add User Code:
System/Partition Master code + [8] + user no.
+
new users code
(
Users 03/33 are preset
User 01 = installer User 03 = partition 1 master
to partition programmers,
User 02 = master User 33 = partition 2 master
but can be changed.)
The Keypad beeps once to confirm that new user was added.
Delete User Code:
System/Partition Master code + [8] + [user no.] + [#] [0]
The user code and all attributes* programmed for this user number,
including any associated RF keys, are erased from the system.
(*except assigned partition)
Authority Level:
System/Partition Master code + [8] + [user no.] + [#] [1]+ auth. level
Factory Defaults:
Authority Levels (see definitions on previous page):
users 04-32/34-49 = 0
0 = standard user 3 = duress
users 03/33 = 4
1 = arm only 4 = partition master (VISTA-20P/PS Series
2 = guest only)
Access Group:
System/Partition Master Code + [8] + [user no.] + [#] [2]+ group (1-8)
Factory Defaults:: none
You can assign users to a group, then set an access schedule that
defines the times this group of users can operate the system. The
system ignores these users outside the scheduled times.
Users Partition:
System Master Code + [8] + [user no.] + [#] [3] + [0] + partition(s) + [#]
(VISTA-20P only)
This command assigns the partitions the user can access. If more
Factory Defaults:
than one, enter partition numbers sequentially, then press [#] to end.
Part. 1 = users 03-32
E.g., master code + [8] + [user no.] + [#] [3] + [0] + [1] [2] + [#] gives
Part. 2 = users 33-49
the user access to partitions 1 and 2 and the common partition.
Partition Entries: 1 = partition 1 and common
2 = partition 2 and common
3 = common partition only
RF User Number:
Master/Part. Prog. Code + [8] + [user no.] + [#] [4]+ zone no.
Factory Defaults:: none
Use this command to assign a wireless button device (keyfob) to this
user (keyfob must be enrolled in system first; see installer).
Zone number: enter the zone number assigned to a button on the
keyfob that will be used for arming/disarming by this user.
Pager On/Off:
Master/Part. Prog. Code + [8] + [user no.] + [#] [5] + 0 or 1
Factory Defaults:
Y
ou can program a user so that a message is sent to a pager
users 01-04 = 0 (off)
whenever this code is used to arm or disarm the system.
users 05-49 = 1 (on)
Paging On/Off: 1 = allow paging; 0 = no paging for this user

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell VISTA-20PSeries and is the answer not in the manual?

Honeywell VISTA-20PSeries Specifications

General IconGeneral
BrandHoneywell
ModelVISTA-20PSeries
CategorySecurity System
LanguageEnglish

Related product manuals