Event Logging Procedures
About Event Logging
The system records various events in a history log, which can be viewed by the master
user on an Alpha Display keypad.
The Event Log holds up to 100 (VISTA-20P/PS Series) or 50 (VISTA-15P Series)
events.
Events are displayed in chronological order, from most recent to oldest.
When the log is full, the oldest event is replaced by the logging of any new event.
Viewing the Event Log
1. + [#] + [6] + [0]
(Master Code)
Alpha Displays:
✱✱✱✱
DISARMED
✱✱✱✱
READY TO ARM
2. The system displays the most recent event as follows:
event number
type of event, identified by its corresponding code
(refer to the code table that follows)
zone or user number (depending on type of event)
partition in which event occurred
time and date of the events occurrence.
3. Pressing [] displays previous events (back in time).
Pressing [#] displays events forward in time.
4. Exit the event log by pressing any key other than []
or [#].
001 E441 U001 P1
12:34AM 01/02/00
Understanding the Type of Event Displayed
If the event code is preceded by an
E
(as in the above display), it means that the
event is new and ongoing; if preceded by an
R,
it means the event has been restored.
Code
Definition
110 Fire Alarm
121 Duress
122 Alarm, 24-hour Silent
123 Alarm, 24-hour Audible
Code
Definition
131 Alarm, Perimeter
132 Alarm, Interior
134 Alarm, Entry/Exit
135 Alarm, Day/Night

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell VISTA-20PSeries and is the answer not in the manual?

Honeywell VISTA-20PSeries Specifications

General IconGeneral
BrandHoneywell
ModelVISTA-20PSeries
CategorySecurity System
LanguageEnglish

Related product manuals