– 51 –
Summary of Audible/Visual Notifications
Fixed-Word Display Keypads
SOUND CAUSE DISPLAY
LOUD,
INTERRUPTED
*
Keypad & Ext.
FIRE ALARM
FIRE
is displayed; zone number of zone in
alarm is displayed. If a fire alarm is
manually activated, zone number 95 will be
displayed.
LOUD,
CONTINUOUS
*
Keypad & Ext.
BURGLARY/AUDIBLE
EMERGENCY ALARM
ALARM
is displayed. Zone number of zone
in alarm is also displayed.
ONE SHORT
BEEP
(not repeated)
Keypad only
a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE.
c. BYPASS VERIFY
a. READY indicator light comes on.
b. Number of the open protection zone
displayed.
c. Zone numbers of the bypassed protection
zones are displayed (one beep is heard for
each zone displayed). Subsequently,
BYPASS
is displayed.
ONE SHORT
BEEP
(once every 40
secs)
Keypad only
a. SYSTEM IS IN TEST MODE
b. LOW BATTERY AT A
TRANSMITTER
a. Opened zone numbers will appear.
b.
BAT
displayed with zone number of
transmitter.
TWO SHORT
BEEPS
Keypad only
ARM AWAY or MAXIMUM
AWAY
is displayed. Red ARMED indicator is
lit.
THREE SHORT
BEEPS
Keypad only
a. ARM STAY, NIGHT-STAY,
INSTANT
b. ZONE OPENED WITH
SYSTEM IN CHIME MODE.
a.
STAY
or
INSTANT
is displayed. Red
ARMED indicator is lit.
b.
CHIME
displayed; zone number of open
protection zone will be displayed if the [
✱
]
key is pressed.
RAPID
BEEPING
Keypad only
a. TROUBLE
b. MEMORY OF ALARM
c. SYSTEM LOW BATTERY
d. EXT. SOUNDER WIRING
FAIL
a.
CHECK
displayed. Zone number of
troubled protection zone is displayed.
b.
FIRE
or ALARM is displayed; zone
number of zone in alarm is displayed
c.
BAT
displayed with no zone ID number.
d.
CHECK 70
is displayed.
SLOW
BEEPING
Keypad only
a. EXIT DELAY WARNING
b. ENTRY DELAY WARNING
a.
AWAY
is displayed.
b.
Exceeding the entry delay time without
disarming causes alarm.
*
If a bell is used as external sounder, fire alarm is
pulsed ring;
burglary/audible emergency is
steady ring
.