Table 2 Operational I/O module status indicators
DescriptionsLowerPowerUpper
• I/O Module is operational.
OffOnOff
• Top port—Fibre Channel drive enclosure signal detected.
• Power—Flashes for about 90 seconds after initial power application,
then remains constant.
• Bottom port—Fibre Channel drive enclosure signal detected.
OnFlashing, then OnOn
• Top port—Fibre Channel drive enclosure signal detected.
• Power—Present.
• Bottom port—Fibre Channel drive enclosure signal detected.
OnOnOn
• When the locate function is active, all three indicators flash
simultaneously. The Locate function overrides all other indicator
functions. Therefore, an error could be detected while the Locate
function is active and not be indicated until the Locate action terminates.
FlashingFlashingFlashing
Table 3 Non-operational I/O module status indicators
DescriptionsLowerPowerUpper
• Top port—Fibre Channel drive enclosure signal detected.
• Power—Present.
• Bottom port—No Fibre Channel drive enclosure signal detected. Check
transceiver and fiber cable connections.
NOTE: This status applies to configurations with and without FC loop switches.
OffOnOn
• Top port—No Fibre Channel drive enclosure signal detected. Check transceiver
and fiber cable connections.
• Power—Present.
• Bottom port—Fibre Channel drive enclosure signal detected .
OnOnOff
• Top port—EMU detected possible transceiver problem. Check transceiver and
fiber cable connections.
• Power—Present.
• Bottom port—Fibre Channel drive enclosure signal detected .
OnOnFlashing
• Top port—Fibre Channel drive enclosure signal detected.
• Power—Present.
• Bottom port—EMU detected possible transceiver problem. Check transceiver
and fiber cable connections.
NOTE: The EMU will not flash the lower indicator on its own. It will flash only
in response to a locate command. You can flash each of the lights independently
during a locate action.
FlashingOnOn
• No I/O module power.
• I/O module is nonoperational.
• Check power supplies. If power supplies are operational, replace I/O module.
OffOffOff
Fiber Optic Fibre Channel cables
The Enterprise Virtual Array uses orange, 50-µm, multi-mode, fiber optic cables for connection to
the SAN. The fiber optic cable assembly consists of two 2-m fiber optic strands and small form-factor
connectors on each end. See Figure 9 (page 29).
28 Enterprise Virtual Array hardware components

Table of Contents

Other manuals for HP 6100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 6100 and is the answer not in the manual?

HP 6100 Specifications

General IconGeneral
BrandHP
Model6100
CategoryStorage
LanguageEnglish

Related product manuals