Interface Access: Console/Serial Link, Web, and Telnet
To re-enable inbound Telnet access:
ProCurve(config)# telnet-server
Outbound Telnet to Another Device. This feature operates indepen-
dently of the telnet-server status and enables you to Telnet to another device
that has an IP address.
Syntax: telnet < ip-address >
For example:
ProCurve# telnet 10.28.27.204
Reconfigure Web Browser Access. In the default configuration, web
browser access is enabled.
Syntax: [no] web-management
To disable web browser access:
ProCurve(config)# no web-management
To re-enable web browser access:
ProCurve(config)# web-management
Reconfigure the Console/Serial Link Settings. You can reconfigure one
or more console parameters with one console command.
Syntax: console
[terminal <vt100 | ansi>]
[screen-refresh <1 | 3 | 5 | 10 | 20 | 30 | 45 | 60>]
[baud-rate
<speed-sense | 1200 | 2400 | 4800 | 9600 | 19200 |38400 | 57600>]
[flow-control <xon/xoff | none>]
[inactivity-timer <0 1 5 10 15 20 30 60 120>]
[events <none | all | non-info | critical | debug]
7-6

Table of Contents

Other manuals for HP ProCurve 2810 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2810 Series and is the answer not in the manual?

HP ProCurve 2810 Series Specifications

General IconGeneral
BrandHP
ModelProCurve 2810 Series
CategorySwitch
LanguageEnglish

Related product manuals