EasyManuals Logo
Home>Huawei>Inverter>SUN2000-215KTL-H0

Huawei SUN2000-215KTL-H0 User Manual

Huawei SUN2000-215KTL-H0
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Before making electrical connections, switch o the disconnector on the
upstream device to cut o the power supply if people may contact energized
components.
Before connecting a power cable, check that the label on the power cable is
correct.
If the equipment has multiple inputs, disconnect all the inputs before
operating the equipment.
Cabling
When routing cables, ensure that a distance of at least 30 mm exists between
the cables and heat-generating components or areas. This prevents damage
to the insulation layer of the cables.
Bind cables of the same type together. When routing cables of
dierent types,
ensure that they are at least 30 mm away from each other.
Ensure that the cables used in a grid-tied PV power system are properly
connected and insulated and meet
specications.
1.4 Installation Environment Requirements
Ensure that the equipment is installed in a well ventilated environment.
To prevent
re due to high temperature, ensure that the ventilation vents or
heat dissipation system are not blocked when the equipment is running.
Do not expose the equipment to
ammable or explosive gas or smoke. Do
not perform any operation on the equipment in such environments.
1.5 Mechanical Safety
Using Ladders
Use wooden or
berglass ladders when you need to perform live working at
heights.
When a step ladder is used, ensure that the pull ropes are secured and the
ladder is held
rm.
Before using a ladder, check that it is intact and conrm its load bearing
capacity. Do not overload it.
Ensure that the wider end of the ladder is at the bottom, or protective
measures have been taken at the bottom to prevent the ladder from sliding.
Ensure that the ladder is securely positioned. The recommended angle for a
ladder against the
oor is 75 degrees, as shown in the following gure. An
angle rule can be used to measure the angle.
SUN2000-(196KTL-H0, 200KTL-H2, 215KTL-H0)
Series
User Manual 1 Safety Information
Issue 07 (2021-07-08) Copyright © Huawei Technologies Co., Ltd. 4

Table of Contents

Other manuals for Huawei SUN2000-215KTL-H0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-215KTL-H0 and is the answer not in the manual?

Huawei SUN2000-215KTL-H0 Specifications

General IconGeneral
BrandHuawei
ModelSUN2000-215KTL-H0
CategoryInverter
LanguageEnglish

Related product manuals