Page #48 background imageLoading...
Page #48 background image
INSTALLATION AND MAINTENANCE - INSTALLATION UND INSTANDHALTUNG
48
HCD3M-04
HC-D3M
47
Sectional Valve - WEGEVENTIL IN SEKTIONSBAUWEISE
AnzugsmomentGeneral clamping torque
D
C
B
F
A
POSITION DESCRIPTION CLAMPING TORQUE
(Nm)
POSITION BESCHREIBUNG ANZUGSMOMENT
(Nm)
load check valve plug
A 50
Verschlusskappe Rückschlagventil
plug to replace pressure relief valve
B 80
Stopfen anstelle Druckbegrenzungsventil
pressure relief valve body
C 80
Druckbegrenzungsventilkörper
pressure relief valve cap
D 20
Abdeckkappe Druckbegrenzungsventil
fittings in service ports A-B-P-T G04 = 60 - U03 = 40
E
Verschlusskappen für Verbraucheranschlüsse A-B-P-T M01 = 80 - M02 = 80
clamping torque auxiliary valve see table (X)
F
Anzugsmoment Sekundärventil siehe Tabelle (X)
ANTISHOCK VALVE PLUG ANTICAVITATION VALVE PLUG COMBINED VALVE PLUG
VERSCHLUSSKAPPE VERSCHLUSSKAPPE VERSCHLUSSKAPPE KOMBINIERTES
SEKUNDÄRDRUCKBEGRENZUNGSVENTIL NACHSAUGEVENTIL VENTIL
25 Nm 25 Nm 30 Nm
ANTISHOCK VALVE BODY ANTICAVITATION VALVE BODY COMBINED VALVE BODY
SEKUNDÄRDRUCKBEGRENZUNGS
- NACHSAUGEVENTILKÖRPER KÖRPER KOMBINIERTES
VENTILKÖRPER VENTIL
60 Nm 60 Nm 50 Nm
PLUG REPLACES VALVE
STOPFEN ANSTELLE SEKUNDÄRVENTIL
60 Nm
TABLE - TABELLE (X)