TYPICAL CURVES - KENNLINIEN
48
HCD3M-04
HC-D3M
10
Sectional Valve - WEGEVENTIL IN SEKTIONSBAUWEISE
OUT IN
Pressure drop (P - T) Druckverlust (P - T)
Druckverlust (P - A/B)
Druckverlust (A/B - T)
HINWEIS: Die angegebenen Werte wurden mit einem
Sektionswegeventil in seiner Standardausfüh-
rung und W001A Kolben gemessen.
NOTE: indicated values have been tested with standard
sectional valve and W001A spools.
Pressure drop (P - A/B)
Pressure drop (A/B - T)
OUT
IN
OUT
IN
0
10
20
30
35
0
Qp
l/min
US-GPM
Δp
bar
psi
20
40
60
80
D3M/1
D3M/3
D3M/6
D3M/9
D3M/12
0
5.3
10.6
15.9
21.2
0
145
290
435
510
0
4
8
12
0
Qp
l/min
US-GPM
Δp
bar
psi
20
40
60
80
D3M/1
D3M/3
D3M/6
D3M/9
D3M/12
0
5.3
10.6
15.9
21.2
0
58
116
174
0
10
20
30
35
0
Qp
l/min
US-GPM
Δp
bar
psi
20
40
60
80
D3M/1
D3M/3
D3M/6
D3M/9
D3M/12
0
5.3
10.6
15.9
21.2
0
145
290
435
510