EasyManuals Logo
Home>Hypertherm>Welding System>Powermax 85

Hypertherm Powermax 85 Service Manual

Hypertherm Powermax 85
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #193 background imageLoading...
Page #193 background image
Component ReplaCement
powermax
65/85
Service Manual 6-11
Replace the work lead
Work lead receptacle
on power supply
Keyed opening at
top of
receptacle
1. Turn OFF the power.
2. Remove the old work lead from the front of the power supply. Turn the work lead connector counterclockwise
approximately 1/4 turn.
3. Pull the work lead connector out of the receptacle.
4. Insert the new work lead connector into the receptacle.
Note: The receptacle is keyed. Align the key on the work lead connector with the opening at the top of the
receptacle on the power supply.
Caution: Make sure you use a work lead that is appropriate for your power supply.
Use a 65A work lead with the Powermax65. Use an 85A work lead with the
Powermax85. The amperage is marked near the rubber boot of the work lead
connector.
Caution: Ensure the work lead is fully seated in the receptacle to prevent overheating.
5. Push the work lead connector all the way into the receptacle on the power supply and turn clockwise, approximately
1/4 turn, until the connector is fully seated against the stop in order to achieve an optimal electrical connection.

Table of Contents

Other manuals for Hypertherm Powermax 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 85 and is the answer not in the manual?

Hypertherm Powermax 85 Specifications

General IconGeneral
BrandHypertherm
ModelPowermax 85
CategoryWelding System
LanguageEnglish

Related product manuals