Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
9090 Disk unit has been modified after the last known status.
Re-IPL the system. If any reference codes are surfaced, go to RCT and use
the new reference code as the entry point to the problem.
If you cannot resolve the problem, contact your next level of support.
SVCDOCS
9091 Incorrect hardware configuration change has been detected.
Re-IPL the system. If any reference codes are surfaced, go to RCT and use
the new reference code as the entry point to the problem.
If you cannot resolve the problem, contact your next level of support.
SVCDOCS
9092 Disk unit requires initialization before use.
Perform SDIOP-PIP26.
SVCDOCS
B3B1 to B3B7 A permanent I/O processor failure occurred IOP
B3B8 Multi-adapter bridge error detected. MA_BRDG
IOP
B3B9 A permanent I/O processor failure occurred IOP
B3E0 to B3E1 I/O processor detected a fault condition. IOP
MA_BRDG
B410 to B411 A permanent I/O processor failure occurred STORIOA
B412 Tape/CD or disk bus interface error occurred
Perform SDIOP-PIP16.
FI01107
FI01140
STORIOA
DEVTERM
B935 Unknown hardware detected FI01101
AJDGP01
IOP
MA_BRDG
BE00 I/O processor detected a fault condition. AJDGP01
IOP
FI01104
MA_BRDG
FF3D I/O adapter detected recoverable error STORIOA
ANYBRDG
FF6D I/O processor detected a recoverable system bus error IOP
ANYBUS
Table 2. Failing Items Details
Failing Item Description Document Description
AJDG301 Vertical Licensed Internal Code Service Functions; APAR or LICTR
AJDGP01 I/O card Licensed Internal Code Service Functions; APAR or LICTR
AJDGP01 I/O processor Licensed Internal Code Service Functions; APAR or LICTR
ANYBRDG System I/O bus or any attached card Problem Analysis; Symbolic FRU Isolation
ANYBUS IOP card bus error Problem Analysis; Symbolic FRU Isolation
BACKPLN Card Enclosure or Planar Board Problem Analysis; Symbolic FRU Isolation
CACHBAT Cache battery pack Problem Analysis; Symbolic FRU Isolation
CACHE Cache adaptor card Problem Analysis; Symbolic FRU Isolation
2749, 2767, 2768, 2842, 2843, 2844, 284B, 284C, 284D, 284E, 286C, 286D, 286E, 286F, 5702
System Reference Codes 153