Hot-swap
power supply
Release
lever
4. If you are instructed to return the power supply, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
Installing the hot-swap power supply
This procedure applies only to the 5U server model with hot-swap power supplies
(Model name: 2582-F4x).
The following items describe the type of power supply that the server supports and
other information that you must consider when you install a power supply:
v To confirm that the server supports the power supply that you are installing, see
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/.
v The server comes standard with one 430-watt hot-swap power supply. The input
voltage is 110 V ac or 220 V ac auto-sensing.
v These power supplies are designed for parallel operation. In the event of a
power-supply failure, the redundant power supply continues to power the system.
The server supports a maximum of two power supplies.
v The server can run fully configured with one power supply. For redundancy
support, you must install the second hot-swap power supply.
Note: You cannot mix high-efficiency and non-high-efficiency power supplies in the
server.
Statement 5:
Chapter 5. Removing and replacing server components 245

Table of Contents

Other manuals for IBM System x3100 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3100 M4 and is the answer not in the manual?

IBM System x3100 M4 Specifications

General IconGeneral
BrandIBM
ModelSystem x3100 M4
CategoryServer
LanguageEnglish

Related product manuals