mexico HE - Installation & Servicing
InstallatIon
FLUE OUTLET
Part No. Description 60/100 Quantity
HE15 HE18 HE24 HE30 HE36
n/a Maximum Flue Length (m) 8 8 8 5 5
201 180 Flue ext. 60/100 7 7 7 6 6
201 189 Terminal Vertical Roof 60/100 1 1 1 1 1
152 258 Weather Collar Pitched Roof 1 1 1 1 1
152 259 Weather Collar Flat Roof 1 1 1 1 1
201 182 90
o
201 183 45
o
201 869 Vertical Connector 1 1 1 1 1
31
FLUE TERMINAL POSITION
The terminal should be positioned so that products of
combustion can safely disperse at all times.
Pluming may occur at the termination so, where
possible, terminal positions where this could cause a
nuisance should be avoided.
Minimum dimensions are shown below
32
FLUE ARRANGEMENT
Note.
The equivalent ue length resistance of the 90
o
elbow kit
(60/100) is 1m and the 45
o
elbow kit (60/100) is 0.75m.
Terminal Position Minimum Dimension
air brick, windows, etc. 300 mm
Below plastic / painted gutters 300 mm
Painted surface 300 mm
Below eaves or balcony 500 mm
Below velux windows 2000mm
Above or side of velux windows 600mm
Note.
The equivalent ue length resistance of the elbow kits are:
90
o
elbow kit = 1m
45
o
elbow kit = 0.6m
RF9807
A
A
B
A
A = 600mm
B = 2000mm
The flue terminal shall not penetrate the shaded area of the roo