44
Installation and Servicing
SECTION 3 - SERVICING
3.10 BURNER INJECTOR REPLACEMENT
1. Refer to Section 3.8.
2. Disconnect the electrical leads from the fan.
3. Remove the clip from the gas valve to
venturi pipe and ease the pipe upwards,
rotate and ease down to remove.
4. Loosen the screw retaining the fan
mounting bracket.
5. Lift and remove the fan and venturi
assembly.
6. Remove the 2 injector housing screws.
7. Withdraw the injector housing.
8. Fit the new injector housing complete with
injector.
9. Reassemble in reverse order, ensuring
that the new gas seal supplied is located
correctly in the injector housing.
10. Check that the boiler operates in both DHW
& CH modes.
4
3
3
3.11 BURNER REPLACEMENT
5
5
6
1. See Section 3.8.
2. Refer to Section 3.4.
3. Undo the two screws and remove the sump cover.
4. Lift the manifold to clear the bottom sealing gasket and remove
manifold.
5. Remove the 2 front xing screws and loosen the 2 rear
extended nuts.
6. Lift off the burner from the combustion chamber. To facilitate
the removal angle the burner as shown.
7. Fit the new burner, replacing any damaged or deteriorating
sealing gasket.
8. Reassemble in reverse order.
9. Check that the boiler operates in both DHW & CH modes.
2
4
3
6
Injector
SERVICING

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL INDEPENDENT COMBI 24 and is the answer not in the manual?

IDEAL INDEPENDENT COMBI 24 Specifications

General IconGeneral
BrandIDEAL
ModelINDEPENDENT COMBI 24
CategoryBoiler
LanguageEnglish

Related product manuals