Installation and Servicing
SECTION 3 - SERVICING
3.30 DHW FILTER & DHW FLOW REGULATOR CLEANING / REPLACEMENT
1. Refer to Sections 3.8.
2. Drain down the boiler. Refer to Sections 3.22.
3. Unplug the electrical lead.
4. Unscrew the thermistor (to facilitate removal a
13mm socket spanner should be used).
5. Fit the new thermistor using the sealing
washer provided.
6. Reassemble in the reverse order.
7. Rell the boiler. Refer to Section 2.16.
8. Check that the boiler operates in both DHW &
CH modes.
3.31 FLOW THERMISTOR REPLACEMENT
4
3
1. Refer to Section 3.8.
2. Drain the DHW system. Refer to Section
3.22.
3. Turn the housing anti clockwise and pull
forward to remove the cartridge.
4. Using a pair of pliers, pull out the plastic
lter/ow regulator.
5. Clean or replace lter as necessary.
6. Reassemble in reverse order.
7. Rell the boiler.
8. Check that the boiler operates in both
DHW & CH modes.
3
4
SERVICING

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL INDEPENDENT COMBI 24 and is the answer not in the manual?

IDEAL INDEPENDENT COMBI 24 Specifications

General IconGeneral
BrandIDEAL
ModelINDEPENDENT COMBI 24
CategoryBoiler
LanguageEnglish

Related product manuals