Comet
4Service
4.1Generalsafetyinformationoninstallation
work
Riskofdamagetomobilitydevice
Collisionscanbecausedifshimringsareremoved
fromthedrivewheelsduringinstallationwork.
Shimringsarefrequentlyplacedbetweendrive
shaftandwheelhubtocompensatetolerances.
Collisionscanbecausediftheseshimringsare
removedandnotre-installed.
–Installallshimringsinexactlythesame
positionstheywereinbeforedismantling.
4.2Troubleshooting
4.2.1Operationalfaults
Proceedasfollowsifyouhaveanyproblems:
1.Firstassessthepossiblecauseoftheproblemusingthe
followingtable.
2.Checkoperatingconsolestatusdisplay.Evaluateash
code.
3.Carryoutnecessarychecksandrepairsasrecommended
inthefollowingtable.
4.2.2Drivefaultdiagnosis
ProblemOthersymptomsPossiblecauseSolution
Documentation
BatteriesdefectiveReplacebatteriesSeeusermanual
Completely
dischargedbattery
Pre-chargebatteries
Powersupplyto
operatingconsole
interrupted
CheckmainfuseSeeusermanualfor
mainfuseposition
Checkcablebetween
modulesforloose
connectionsor
damage
SeeReplacingpower
module
Statusdisplayon
operatingconsole
doesnotilluminate
Operatingconsole
defective
Replaceoperating
console
See4.5.1Replacing
operatingconsole,
page11
Scooterwillnotstart
Statusdisplayon
operatingconsole
ashing
Variouscauses
AssesserrorcodeSeecontrolsuser
manual
Drivemotor(s)
defective
Replacemotor(s)
See
Scooterjuddersindrivemode
None
Drivelever
potentiometer
defective
Replace
potentiometer
See4.5.3Replacing
potentiometer,page
12
None
BatteriesdefectiveReplacebatteriesSeeusermanual Batteriesnotbeingcharged
LEDsashingon
charger
ChargerdefectiveReplacechargerSeechargeruser
manual
Operatingconsole
defective
Replaceoperating
console
See4.5.1Replacing
operatingconsole,
page11
Scooterrunstooslowly
None
BatteriesdefectiveReplacebatteriesSeeusermanual
Curvecontroldevice
forbendtravelnot
adjusted
Adjustcurvecontrol
device
Scooterdoesnotreducespeed
onbends
None
Curvecontroldevice
defective
Replacecurve
controldevice
See4.9.4Replacing
curvecontroldevice,
page28
81603798-B