Voltage Setting Commands
Copyright© Itech Electronics Co., Ltd. 25
Chapter7 Voltage Setting Commands
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]
This command is used to set output Voltage value.
Command syntax
[SOURce:]VOLTage[:LEVel] <NRf>
Arguments
num|MIN|MAX|UP|DOWN|DEF
Unit
V mV kV
*RST Value
MIN
Query syntax
[SOURce:]VOLTage[:LEVel]?
Arguments
[MIN|MAX]
Returns
<NR2>
[SOURce:]OLTage[:LEVel]:UP[:IMMediate][:AMPLitude
]
This command is used to increase a voltage step for voltage channel.
Command syntax
[SOURce:] VOLTage[:LEVel]:UP[:IMMediate][:AMPLitude]
Arguments None
Related Command
[SOURce:]VOLTage[:LEVel][:IMMediate]:STEP[:INCRement]
[SOURce:]VOLTage[:LEVel]:DOWN[:IMMediate][:AMPL
itude]
This command is used to decrease a voltage step for voltage channel.