Compound Control Commands
Copyright© Itech Electronics Co., Ltd. 28
Chapter8 Compound Control Commands
[SOURce:]APPLy
This command is used to set the voltage and current values of a certain
channel. It equals to the combination of instructions below.
INST <nr1>
VOLT <nr2>
CURR <nr3>
Command syntax
[SOURce:]APPLy <nr1>, <nr2>, <nr3>
Arguments 1:
CH1|CH2|CH3
Optional parameter 2:
num|MIN|MAX|UP|DOWN|DEF
Unit
V mV kV
Optional parameter 3:
num|MIN|MAX|UP|DOWN|DEF
Unit
A/ mA/ uA
Query syntax
APPL? <nr>
Arguments
CH1|CH2|CH3
Returns
<volt>, <curr>
Note: When there is no default parameter, current value will not be changed.