Measurement Commands
Copyright© Itech Electronics Co., Ltd. 29
Chapter9 Measurement Commands
MEASure[:SCALar]:CURRent[:DC]?
FETCh:CURRent[:DC]?
These two commands are used to read the output current of power supply.
Command syntax
MEASure[:SCALar]:CURRent[:DC]? <nr>
FETCh:CURRent[:DC]? <nr>
Arguments
CH1|CH2|CH3|ALL
Returns
If optional parameter CH1|CH2|CH3 is applied to specify measure channel,
return actual current of the specified channel;
If optional parameter All is applied, return actual current of all channels;
If no optional parameter is applied, return actual current of current channel.
Unit
A
Example
MEAS:CURR?
FETC:CURR?
MEASure[:SCALar][:VOLTage][:DC]?
FETCh[:VOLTage][:DC]?
These two commands are used to read the output voltage of power supply.
Command syntax
MEASure[:SCALar][:VOLTage][:DC]? <nr>
FETCh[:VOLTage][:DC]? <nr>
Arguments
CH1|CH2|CH3|ALL
Returns
If optional parameter CH1|CH2|CH3 is applied to specify measure channel,
return actual voltage of the specified channel;