EasyManuals Logo
Home>ITech>Power Supply>IT-M3400 Series

ITech IT-M3400 Series User Manual

ITech IT-M3400 Series
153 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #130 background imageLoading...
Page #130 background image
Technical Specification
Internal
Resistance
(CV Prior-
ity mode)
Range
0-1000mΩ
Setup Resolution
0.1mΩ
Accuracy
2%*Rmax
CP
Range
-400W~400W
Setup Resolution
0.1W
Accuracy
<1.0% Pmax
CR mode(CC
Priority
mode)
Range
1.5-1000Ω
Resolution Min.0.1Ω
Accuracy
Rmin(Vreal-Vmax*0.1%)/Rset -Imax*0.2% Rmax
(Vreal+Vmax*0.1%)/Rset +Imax*0.2%
Output Read-back
Read-back
current
Range
-12A~12A
Resolution 1mA
Accuracy
≤0.1%+0.1%FS
Read-back
Voltage
Range
0-150V
Resolution 10mV
Accuracy
<0.1% Umax
Read-back
Power
Range
-400W~400W
Resolution 0.1W
Accuracy
<1% Pmax
Temperature Coefficient
Temperature
Coefficient
Voltage Temperature
Coefficient
100ppm/℃
Current Temperature
Coefficient
50ppm/℃
Regulation
Load
Regulation
Voltage
≤0.05% Umax
Current ≤0.05% Imax
Line
Regulation
Voltage
≤0.05% Umax
Current ≤0.05% Imax
Ripple
Ripple
Voltage ≤300mVp-p
Current ≤30mArms
value voltage rise/fall time
Rise time
Voltage(No load)
20ms
Rise time
Voltage(Full load)
50ms
Fall time
Voltage(No load)
20ms
Copyright © Itech Electronic Co., Ltd.
119

Table of Contents

Other manuals for ITech IT-M3400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3400 Series and is the answer not in the manual?

ITech IT-M3400 Series Specifications

General IconGeneral
BrandITech
ModelIT-M3400 Series
CategoryPower Supply
LanguageEnglish

Related product manuals