Technical Specification
Fall time
Voltage(Full load)
20ms
Transient
Response
Time
Voltage
≤2mS
Output Protection range
OCP -12.5A or 12.5A
OVP 155V
OPP -410W or 410W
External analog (optional)
Voltage programming
External 0V~10V is 0~150V
Voltage monitoring
External 0V~10V is 0~150V
Current programming
External -10V~10V is -12A~12A
Current monitoring
External -10V~10V is -12A~12A
AC parameters
Voltage range
100VAC -240VAC
OVP 264VAC
UVP 90VAC
Frequency
47Hz~63Hz
Max. current (rms) 2Aac (AC220)
DC Offset
-0.1A~+0.1A
Environment
Working temperature
0- 40 °C
Storage temperature
-20- 70℃
Noise 60dB
External temperature measurement
Measurement range
-20℃——120℃
Measurement accuracy
±1℃
Measurement resolution 0.1℃
Efficiency
Max. efficiency (Full-
load)
88%
Communication(Optional)
Communication interfaces
RS232/USB/RS485/CAN/LAN/GPIB/Analog
Mechanical parameters
Size and weight
450mm*214mm*43.5mm
Net weight 5kg
Copyright © Itech Electronic Co., Ltd.
120

Table of Contents

Other manuals for ITech IT-M3400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3400 Series and is the answer not in the manual?

ITech IT-M3400 Series Specifications

General IconGeneral
BrandITech
ModelIT-M3400 Series
CategoryPower Supply
LanguageEnglish

Related product manuals