Calibration Command
Copyright© Itech Electronics Co., Ltd. 101
Example
CAL:PROG:CURR 15.0
CALibrate:EQUal:INPut:CURRent:LEVel
This command is used to set calibration point of current sharing input current.
Command syntax
CALibrate:EQUal:INPut:CURRent:LEVel <P0|P1>
Arguments
P0|P1
Example
CAL:EQU:INP:CURR P0
CALibrate:EQUal:INPut:CURRent[:DATA]
This command is used to set calibration data of current sharing input current.
Command syntax
CALibrate:EQUal:INPut:CURRent[:DATA
Arguments
NRf
Unit
A
Example
CAL:EQU:INP:CURR 12.0A
CALibrate:EQUal:OUTPut:CURRent:LEVel
This command is used to set calibration point of current sharing output current.
Command syntax
CALibrate:EQUal:OUTPut:CURRent:LEVel <P0|P1>
Arguments
P0|P1
Example
CAL:EQU:OUTP:CURR:LEV P0
CALibrate:EQUal:OUTPut:CURRent[:DATA]
This command is used to set calibration data of current sharing output current.