Input Measuring Commands
Copyright© Itech Electronics Co., Ltd. 26
Chapter6 Input Measuring Commands
MEASure[:SCALar]:VOLTage[:DC]?
This command is used to enquire the actual output voltage.
Command syntax
MEASure[:SCALar]:VOLTage[:DC]?
Arguments
None
Returns
〈NRf〉
Unit
V
Example
MEAS:VOLT?
FETCh[:SCALar]:VOLTage[:DC]?
This command is used to fetch the DC voltage value in buffer.
Command syntax
FETCh[:SCALar]:VOLTage[:DC]?
Returns
<NRf>
Unit
V
MEASure[:SCALar]:CURRent[:DC]?
This command is used to enquire the latest DC current value.
Command syntax
MEASure[:SCALar]:CURRent[:DC]?
Arguments
None
Returns
<NRf>