EasyManuals Logo
Home>ITech>Power Supply>IT6532D

ITech IT6532D User Manual

ITech IT6532D
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
Wave Operation Command
Copyright© Itech Electronics Co., Ltd. 67
Query syntax
SEQuence[:STEP]:CURRent? <NR1>,[MINimum|MAXimum]
Returns
NRf
SEQuence[:STEP]:LOAD:CURRent?
This command is used to edit the load current of specified step of a
sequence file. This command is prepared for IT6500C model.
Arguments
<NR1>,MINimum|MAXimum|NRf
Unit
s
Example
SEQ:LOAD:CURR 1,0.5
Query syntax
SEQuence[:STEP]:LOAD:CURRent? <NR1>
Returns
<NRf>
SEQuence[:STEP]:WIDTh
This command is used to edit the width of specified step of the wavefile .
Command syntax
SEQuence[:STEP]:WIDth <NR1>,<MINimum|MAXimum|NRf>
Arguments
<1~10>,MINimum|MAXimum|NRf
Unit
s
Example
SEQ:WIDT 1,64
Query syntax
SEQuence[:STEP]:WIDTh? <NR1>,[MINimum|MAXimum]
Returns
NRf

Table of Contents

Other manuals for ITech IT6532D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6532D and is the answer not in the manual?

ITech IT6532D Specifications

General IconGeneral
BrandITech
ModelIT6532D
CategoryPower Supply
LanguageEnglish

Related product manuals