Technical Specifications
Copyright ©ITECH Electronic Co., Ltd. 86
±(0.04% per degree from 25°C)
AC
Current(rms)
Range
0-144Arms
Resolution
10mA
Accuracy
±0.3%+(0.3%+0.2%×Kfreq)×FS
*2
±(0.04% per degree from 25°C)
AC
Current(peak)
Range
0-432Apeak
Resolution
10mA
Accuracy
±0.3%+(0.3%+0.2%×Kfreq)×FS
*2
±(0.04% per degree from 25°C)
Power
Resolution
10mW
Accuracy
±0.4%+(0.4%+0.2%×Kfreq)×FS
*2
±(0.04% per degree from 25°C)
Phase Angle
Range 0-360°
Resolution 1°
Accuracy
±1°(45-65Hz)
*5
Frequency
Range
10-5KHz
Resolution
0.1Hz
Accuracy ±0.1%+0.1Hz(45Hz-999.9Hz)/±0.1%+1Hz(1KHz-5KHz)
*4
Other
Protection
OVP, OPP, OCP, OTP
Interface
GPIB, USB, LAN, RS232, CAN
37u
*1
: Meet the voltage accuracy requirements: Slow loop speed: 10-100Hz; Fast
loop speed: 10-5KHz.
*2
: FS corresponds to the full range:Vrms=300Vac;Irms=144A;
Ipk=432A;P=18KVA;
*3
: The minimum voltage of THD test is 10Vac (Auto mode) and 20Vac (High
mode).
The maximum distortion test is carried out by outputting the maximum current
to linear load under 125Vac (Auto mode) and 250Vac (300V mode).
*4
: The test frequency accuracy should ensure that the minimum voltage is
30Vac.
*5
: The test mode is Fast.