25
8.1D No Heat or Not Enough Heat (All Models)
• Symptoms: Low speed pump 1 or circulation pump (heating pump) is turning, panel heat
indicator not lit, panel is ashing FL1.
Standard Troubleshooting Approach
Is the low speed pump
or circulation pump (Heat
Pump) moving water?
Verify hot tub is in
standard ltration mode
(page 7) then perform
step below.
Remove switch wires
from board. Increase set
temperature to initiate a
heat call, then jumper ow
switch wires together (Fig.
9-10). Does heat indicator
appear and FL1 error
message disappear?
Test ow or pressure
switch with ohmmeter for
continuity (0Ω) across
switch terminals (Fig. 11)
Does meter read continuity
(0Ω) with pump on?
Clean connectors between
ow cable and switch.
1. Remove lter and
allow air to bleed
out of cartridge.
2. Check for proper
water level.
3. Check for clogged/
excessively dirty
lter.
4. Check for blockage
at lter wall tting.
5. Check for sticking
weir.
6. Is pump moving
water?
Remove ow or pressure
switch connector from
circuit board test point
23 (Fig. 10). Place
jumper across exposed
connector pins*. Does
heat indicator appear
and FL1 error message
disappear?
Repair or replace ow or
pressure sensor cable.
Remove ow or pressure
switch and inspect
for debris blockage.
Remove blockage or
replace switch.
Re-install ow or
pressure switch. Install
ow switch with arrow
pointing in direction of
ow. Make sure magnet
arm doesn’t bottom out
in tting (Fig. 12).
Models with a circulation
pump:
See Section 8.12 (pg.
40)
Models without a
circulation pump:
See Section 8.7 (pg. 35)
Replace circuit board.
No
Yes
*Lightly scrape
contact pins at
point 23 with a
razor blade or
sandpaper to re-
move conformal
coating or oxida-
tion form contact
surface.
No
No
No
Yes
Yes
Yes
Yes
No
Fig. 9
Fig. 10
Fig. 11
Temporarily Jumper
Flow or Pressure
Switch Cable Wires
Together as Shown.
Fig. 12
FLOW
Incorrect
Orientation
Correct
Orientation
FLOW
Pipe
End View
correct
incorrect
Arrows
not
aligned
Arrows
aligned
Temporarily
Short Pins
with Jumper
#6560-864
Flow
Cable
22
23
Infinite Ω
Continuity 0 Ω
Pump off
Pump on
Open
Closed
Jumper
Jumper
DCV ACV
DCA
OFF
1000
200
20
2000m
200m
2000k
200k
20k
2000
200
10A
200m
20m
2000µ
200µ
+
750
200
DCV ACV
DCA
OFF
1000
200
20
2000m
200m
2000k
200k
20k
2000
200
10A
200m
20m
2000µ
200µ
+
750
200
Correct
Orientation
DCV ACV
DCA
OFF
1000
200
20
2000m
200m
2000k
200k
20k
2000
200
10A
200m
20m
2000µ
200µ
+
750
200
DANGER: Electrical Shock Hazard Exists!
High Voltage Present on Circuit Board. Use
Extreme Caution while Servicing Circuit Board.

Table of Contents

Other manuals for Jacuzzi J-200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jacuzzi J-200 Series and is the answer not in the manual?

Jacuzzi J-200 Series Specifications

General IconGeneral
BrandJacuzzi
ModelJ-200 Series
CategoryHot Tub
LanguageEnglish

Related product manuals