37
Turn power to hot tub off and on.
Wait approximately two minutes for
lter cycle to begin and turn on the
circulation pump and CLEARRAY (J-LX,
J300 and J200 with circ pump Models)
or Pump 1 and CLEARRAY (J200
Models).
DO NOT press either JETS button at
this time or the CLEARRAY will shut off!
Is lter cycle 1 running?
Is 120 VAC* or 240 VAC present at
circuit board CLEARRAY outputs?
Test points 16 and 17, See pages
50-53.
*Convertible J-210, J-315, J-325 models
only.
Is there current draw (0.4 Amp) on the
CLEARRAY? Check with clamp-on
ampmeter.
Current draw is proof that CLEARRAY
is working. Read steps outlined above
to ensure customer understands the
logic.
Replace circuit board.
Replace control panel.
Replace circuit board.
Turn power off, plug in spare
control panel, then turn power
on. Wait approximately 2
minutes for lter cycle to begin.
Is lter cycle running?
Yes
No
No
Yes
Yes
No
Yes
No
DANGER: Electrical Shock Hazard Exists!
High Voltage Present on Circuit Board. Use
Extreme Caution while Servicing Circuit Board.
8.9 2012+ CLEARRAY Not Working
Verify that the CLEARRAY system should be running before proceeding (no error message, not in summer logic.
CLEARRAY turns off when either jets button is pressed and will remain off for 5 minutes after function ends.
Diagnostic Tools: Clamp-on Ammeter, Voltmeter
Suggested Spare Parts: CLEARRAY ballast, UV bulb, circuit board, control panel
Standard Troubleshooting Approach. Refer to pages 50-53 for testing points.
This applies to 2011-2013 J300 Models not 2014+
Is the green light lit on the
ballast?
Yes
Yes
Turn power off, plug in spare
panel, then turn power on. Is
CLEARRAY indicator lit?
Replace control panel.
Replace circuit
board.
No
Replace ballast.
No
Is the red light lit on the
ballast?
Yes
Replace UV bulb.
No
1
2
0
-
230
V
Ballast
UV bulb