23
5.2.6 OPTIO CAN, Pulse/Dir, Second Encoder Channel
A CAN interface for communication with the
Signateq® measuring amplifier is implemented as
standard. It is possible to have a Pulse/Dir or a second
encoder channel instead.
CAN (standard)
for communication with the Signateq® measuring ampl.
Pulse/Dir (optional)
Enter settings in menu setup / basic settings:
PULSE / DIRECTION CONTROL, MODE 2,
Parameter MODE and INC PER PULSE
Pull up 2,7kΩ to 5V, differential input 26LS32
Pull up 2,7kΩ to 5V, differential input 26LS32
Middle level: Pull up 2,7kΩ to 5V, pull down 2.2kΩ,
differential input 26LS32
Middle level: Pull up 2,7kΩ to 5V, pull down 2.2kΩ,
differential input 26LS32
Second Encoder channel (optional)
ENCODER 2
Electronic gear, MODE 1,
Parameter SYNCH RATIO 10 = 1:1
Pull up 2,7kΩ to 5V, differential input 26LS32
Pull up 2,7kΩ to 5V, differential input 26LS32
Middle level: Pull up 2,7kΩ to 5V, pull down 2.2kΩ,
differential input 26LS32
Middle level: Pull up 2,7kΩ to 5V, pull down 2.2kΩ,
differential input 26LS32