7
1 Characteristics XENAX® Xvi 75V8S
1.1 Electronics / Firmware
Description
Data
Interfaces
Ethernet, TCP/IP, http web server
Puls/direction, Master Encoder, I/O
I
2
C Master/Slave, Start-up Key
USB (standard) or RS232 (optional), CAN for Signateq®
measuring amplifier
Bus, multi-axis operation
EtherCAT (CoE), DS402
Ethernet POWERLINK, DS402
CANopen, DS 402
PROFINET (PROFIdrive)
EtherNet/IP, DS402
Ethernet Switch, TCP/IP
Operation Modes
Standard Servo (MODE 0)
Multi axis operation (Master/Slave, Gantry)
Electronic gear (MODE 1) optional
Pulse/Direction (MODE 2) optional
Safety Motion Unit SMU
Security module, 2-channel monitoring
TÜV certified
SIL 2 Safety Integrity Level 2
Cat 3 Category 3
PL d Performance Level d
MTTFd 1733313 h
Status indication
7-Segment LED
Input digital
12 x 24V Pull down
Output digital
8 x 24V, 100mA Source or 400mA Sink
Input function
8 inputs to start a function or program
Output function
8 outputs to indicate a condition
Reference for rotary motors
free to define, incl. external sensor
Index
50 motion moves (accl. / speed / distance, position)
Profile
5 extended motion profiles with 7 profile segments each.
Number of application programs via input
15, Input 9-12 binary coded (MODE >=10)
Firmware update
Over TCP/IP, Flash-memory internal
Application and parameter update
Over TCP/IP, Flash-memory internal
1.2 Performance / Options
„LG“ logic supply
24VDC / max. 1.3 A
„PW“ power supply motor
12-75VDC
3- Phase Output frequency
0-599 Hz
Nominal current
0-8A
Peak current
18A
Continuous power / dissipation loss
Typical 48V / 3A / 150W / η 85% / Pv = 22W
Temperature monitoring output stage
Shutdown at 80°C
Excess voltage observation
> 85V
Under voltage observation
< 10V
Ballast circuit
up to 80W
Fuse power
10AF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jenny Science XENAX Xvi 75V8S and is the answer not in the manual?

Jenny Science XENAX Xvi 75V8S Specifications

General IconGeneral
BrandJenny Science
ModelXENAX Xvi 75V8S
CategoryController
LanguageEnglish