8
Motor temperature observation with LINAX®, ELAX®
and ROTAX®, sensor in coils
Shutdown at 80°C
PLC Input
8 Inputs, 24V
PLC Input BCD
4 Inputs, 24V, binary coded for program selection
PLC Output
8 Outputs, 24V, Source 100mA, Sink 400mA, Source/Sink
Options
EtherCAT (CoE)
DS402, Beckhoff®, OMRON®, TRIO® MC
POWERLINK (CoP)
DS402, B&R®
CANopen
DS402
EtherNet/IP
DS402, Allen-Bradley
PROFINET (PROFIdrive)
SIMATIC, SIMOTION, SINUMERIK
SMU Safety Functions
STO Safe Torque Off
SS1 Safe Stop 1
SS2 Safe Stop 2
SLS Safely-Limited Speed
Start-up Key
ID number for Master Slave and application memory
Force Processes
Enabled by default
Controllable Motor-Types
LINAX®, ELAX®, ROTAX® and third party motors enabled by
default
1.3 Dimensions
Dirt resistance
IP 20
Weight
Standard 840g, with bus module 880g
Case
Chrome steel
Ground plate
Chrome steel