10.18.4 Reference to Mechanical Stop
Selection REFERENCE LIMIT STOP
After the ordinary reference of a LINAX® or ELAX®, it
is possible drive to a mechanical stop.
Important: This function is optional and has no
influence to the absolute positioning counter.
CREEP DIR
POSITIVE (Travel direction positive)
NEGATIVE (Travel direction negative)
CREEP SPEED
Speed to mechanical stop [Inc/s].
CURRENT LIMIT
Nominal motor current [x10mA] during reference
Power F = motor current x force constant
REF WINDOW
Maximal allowed variation compared to last REF
position [Inc].
REF WINDOW = 0, testing off
Output Function REF = 1
REF WINDOW = 1, testing on
Variations within allowed tolerance (REF Window):
Output function REF = 1, current REF position will be
new reference position.
Variations out of allowed tolerance:
Output function REF = 0,
The subsequent reference will be the new reference
position.