Operation manual
2 2
2.2 Overview of operations
Step 1 Turn on the power of the main unit.
Check to see if there is no substance such as a board or tool inside the machine.
Rotate the main switch to the right to check the air meter (pressure gauge).
After Windows XP and the main unit software start up in this order, the message
appears on the screen.
When you select <OK>, the axes of the machine start retuning to their respective
home positions.
When you return the axes to their home positions (by pressing <OK>
on the screen above), the machine starts operating. To avoid risk
of injury, never put your hand or head inside the machine.
Only after you check to see if there is no substance such as a
wrench that may be in contact with the head inside the machine,
return the axes to the home positions.
Select <OK>.
All axes move, and start returning
to their home positions.
Check the air meter
(pressure gauge).
<Proper pressure>
0.5Mpa±0.05
* If the pressure is less than 0.4
Mpa, check the air system.
WARNING
Turn the main switch to the right
by 90 degrees.
<Power: OFF> <Power: ON>