dot3PauseTable, and show snmp mib walk dot3ControlTable commands to display
the output at the table level.
■
When you issue the request system power-off command, the switch halts instead
of turning off power.
■ In the J-Web interface, the Ethernet Switching monitoring page might not display
monitoring details if there are more than 13,000 MAC entries on the switch.
■ In the J-Web interface, changing the port role from Desktop, Desktop and Phone,
or Layer 2 Uplink to another port role might not remove the configurations for
enabling dynamic ARP inspection and DHCP snooping.
■ On EX8200 switches, if IS-IS is enabled on routed VLAN interfaces (RVIs), IS-IS
adjacency states go down and come up after a graceful Routing Engine switchover
(GRES).
■ When an external RADIUS server goes offline and comes back online after some
time, subsequent captive portal authentication requests might fail until the authd
daemon is restarted. As a workaround, configure the revert interval—the time
after which to revert to the primary server—and restart the authd daemon.
■ Momentary loss of an inter-Routing Engine IPC message might trigger the alarm
that displays the message Loss of communication with Backup RE. There is no
functionality affected.
Interfaces
■ EX Series switches do not support queued packet counters. Therefore, the queued
packet counter in the output of the show interfaces interface-name extensive
command always displays a count of 0 and is never updated.
■ The following message might appear in the system log:
Resolve request came for an address matching on Wrong nh nh:355,
type:Unicast...?
You can ignore this message.
■ On EX3200 and EX4200 switches, when port mirroring is configured on any
interface, the mirrored packets leaving a tagged interface might contain an
incorrect VLAN ID.
■ On EX8200 switches, port mirroring configuration on a Layer 3 interface with
the output configured to a VLAN is not supported.
■ On EX8200 switches, when an egress VLAN that belongs to a routed VLAN
interface (RVI) is configured as the input for a port mirroring analyzer, the
analyzer incorrectly appends a dot1q (802.1Q) header to the mirrored packets
or does not mirror any packets at all. As a workaround, configure a port mirroring
analyzer with each port of the VLAN as egress input.
■ The following interface counters are not supported on routed VLAN interfaces
(RVIs): local statistics, traffic statistics, and transit statistics.
■ EX Series switches do not support IPv6 interface statistics. Therefore, all values
in the output of the show snmp mib walk ipv6IfStatsTable command always display
a count of 0.
192 ■ Limitations in JUNOS Release 10.1 for EX Series Switches
JUNOS 10.1 Software Release Notes