CONTRAST ADJUSTMENT (SDTV)
Measuring Instruments Signal generator (Crosshatch signal)
Oscilloscope
Card (Slot) Component/RGB Input Card (Slot 1)
Test Points TP-47G [CRT SOCKET PWB]
TP-GND [CRT SOCKET PWB]
Adjustment Points S*01 (Contrast) [Service Menu]
Notes:
Perform the following adjustments after completing
the 1080/60i signal Contrast adjustment.
Set the CONTRAST data in the Setup Menu to "00".
The SR value (see the description of the HDTV
Contrast Adjustment) becomes the reference value
for the following adjustments. When this data is
changed, it is required to re-adjust the data of all of
the adjustment signals (HDTV, SDTV and NTSC/PAL).
When re-adjusting the 1080/60i signal, use the SI.
(1) Apply the 480/60i crosshatch signal to INPUT A (Terminal
Y on the Component/RGB Input Card).
(2) Set the CONTRAST potentiometer on the front panel to
the center click position.
(3) Connect the oscilloscope across TP-47G and TP-GND.
(4) Adjust SE01 in the Service Menu to set the voltage
amplitude <A> in the figure on the right to the voltage
shown in the Table2.
(5) Vary the adjustment signal and adjustment data, and re-
perform adjustments in steps 1 to 4 above (see Table 2).
1 Vertical interval
(V. sync)
<A>
Adjustment Signal
Adjustment Data
Adjustment Voltage <A>
480/60i SE01 36 V ± 2 V
576/50i SF01 36 V ± 2 V
480/60p SG01 35 V ± 2 V
576/50p SH01 35 V ± 2 V
Table 2

Table of Contents

Other manuals for JVC DT-V1710CG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JVC DT-V1710CG and is the answer not in the manual?

JVC DT-V1710CG Specifications

General IconGeneral
BrandJVC
ModelDT-V1710CG
CategoryMonitor
LanguageEnglish

Related product manuals