Assembling and disassembling the
battery
Mounting the batteries
Guide battery holder with the bent
side through the notches.
! Insert battery between the battery
holders
! Screw on the positive pole cable
! Slide the protection cover on the
positive pole
Screw on the negative pole cable.
Guide the ventilation hose through
the notch.
! Place on the battery cover
! Lead the battery holders through
and screw them down tight
Taking-out the batteries
When disassembling the battery, the
negative pole cable is unscrewed
before the positive pole cable.
Checking and topping-up the
battery acid level
Always heed safety precautions for
handling batteries!
! Unscrew cellular seals
! Draw a samble from each cell with
the battery hydrometer
! Return each acid sample to the
same cell
At 20 °C, the acid of a fully-charged
battery has a specific weight of
1,28 kg/l.
The acid of a partially-charged
battery has a specific weight
between 1,00 and 1,28 kg/l.
The specific gravity of the
electrolyte must be the same in all
cells.
Specific weight under 1,15 kg/l.
! If the battery acid level is too low,
top-up the cells with distilled water
until the top edge of the plates is
just covered with liquid
! Charge the battery until a specific
weight of 1,28 kg/l is reached
Charging the battery
Always heed safety precautions for
handling batteries!
Warranty is valid only when using
the batteries and charging units
stipulated by Kärcher.
Charge the battery with smallest
possible current.
It is essential to observe the
instructions provided by the
manufacturerer of the charging unit.
! Connect the negative pole cable of
the battery charger with the
negative pole connection of the
battery.
! Connect the positive pole cable of
the battery charger with the positive
pole connection of the battery.
! Switch on battery charger and
insert mains plug
Note:
Use a fully-automatic battery charger
6.654-083 by the company.
Kärcher company.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kärcher KMR 1000 T and is the answer not in the manual?

Kärcher KMR 1000 T Specifications

General IconGeneral
BrandKärcher
ModelKMR 1000 T
CategoryFloor Machine
LanguageEnglish

Related product manuals