6.6 Circuit examples
6.6.1 Instructions to the following circuit example
In the following circuit example the drive converter is connected via the F5-AIC with a
LCLltertothesupplysystem.ThetemperaturemonitoringoftheLCLlterisdoneby
the F5-AIC.
The inputs and outputs are pre-programmed for the following circuit example.
NOTICE
For a safe function of the AIC system use models with positively driv-
en auxiliary contacts for power contactors K2 and K3 (pre-charging and
main contactor). Thus, safe interlocking at defective contactor is guaran-
teed even in case of failure.