EasyManuals Logo
Home>Kohler>Inverter>13.5CCOZ

Kohler 13.5CCOZ User Manual

Kohler 13.5CCOZ
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #89 background imageLoading...
Page #89 background image
6-10 Installation TP-5592 7/96
Closed/Heat Exchanger
Closedheatexchangercoolingisthebestalternativefor
most applications. Kohler Co. recommends using
closed heat exchanger cooling if the craft is operated in
saltwater or water with high silt content.
Provide service accessibility for the water-cooled
exhaust manifold pressure cap. Mount the coolant
recovery tank either to engine or craft stringer. Mount
the coolant recovery tank so that its surface level is the
same height or 2 in. (5 cm) max. below the level of the
pressure cap. See Figure 6-12 for a typicalinstallation.
See Figure 6-11 for coolant recovery tank connections.
Use supplied hose to connect to coolant recovery tank.
NOTE
If not using a coolant recovery tank, be sure that the
overflow hose is not immersed in the bilge water to
prevent bilge water from siphoning backinto thecooling
system.
2
1
DA-250000-H
1. Overflow tube
2. Cooling system pressure cap
Figure 6-11. Coolant Recovery Tank Connections

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 13.5CCOZ and is the answer not in the manual?

Kohler 13.5CCOZ Specifications

General IconGeneral
BrandKohler
Model13.5CCOZ
CategoryInverter
LanguageEnglish

Related product manuals